Pipe Flow and Pressure Drop
Size a line or check a design: enter the flow, pipe and fluid to see the pressure drop and flow regime instantly.
Pipe and flow
The internal bore, not the nominal size. 4-inch Schedule 40 steel is about 102.3 mm.
Fluid
1 mPa·s = 1 centipoise.
Pressure drop
kPa
How it works.
Velocity is the flow rate divided by the bore area. The Reynolds number is ρVD/μ. Below 2,300 the flow is treated as laminar (friction factor 64/Re); above 4,000 as turbulent, with the Colebrook–White equation solved iteratively; between the two the flow is transitional and the result is uncertain.
Pressure drop uses the Darcy–Weisbach equation, Δp = f (L/D) ρV²/2, for a straight, full, circular pipe with incompressible flow. Fittings, valves, elevation changes and compressibility (important for gases over long lines) are not included.
Use the results for estimates and learning. Check design decisions against the applicable codes and with a qualified engineer.
More tools
Engineering Unit Converter
Convert pressure, energy, power, flow, temperature and more, and see every unit at once.
Open tool EngineeringElectrical Power Calculator
Single-phase and three-phase power from current, current from power, and Ohm’s law.
Open tool EnergyEnergy Use and Cost Calculator
List your appliances to see daily, monthly and yearly energy use, cost and where the energy goes.
Open tool